The CIE-A-200 Addressable Fire Alarm Control Panel is a one loop panel capable of supporting up to 200 devices* with a maximum loop length of 2KM, the panel also provides two configurable monitored input circuits, 2 configurable monitored output circuits, 2 configurable + 1 fault relay and also a Peripheral bus circuit to add up to 8 repeater panels.
The system may be configured utilising 3 alarm stages with full ‘Zone to Zone’ Cause and Effect across all 32 panel zones with provision to include alarm confirmation and delay timers. An additional 32 output zones are also provided for more complex Cause and Effect programming.
The CIE-A-200 control panel is compatible with Fike’s addressable range of devices and utilizes soft addressing principles eliminating the need for the installer to physically address each device whilst also eradicating time spent on faults caused by duplicate addressing. The operating parameters of the devices are configured either from the panel or via the OSP programming software and are then stored within the Flash memory of the device itself. This enhanced digital protocol means less information is needed to be sent between the detector and the host control panel, resulting in faster, more reliable communication.
- Dimensions Panel (WxHxD): 353mm x 333mm x 117mm
- Operating Temperature: +5°C to +40°C
- IP Rating IP30
- Main Supply Input: 230V AC Nominal
- Standby Battery Requirement: 2 x 7Ah 12V Sealed Lead Acid (2 x 12 Ah with extended battery box)
- Max Number of Loops: 1
- Max Loop Length: 2000 Metres
- Max Conductor Resistance: 24 Ohms
- Loop Loading: 450 DLU (200 Devices Max)*
- Loop Operating Voltage: 40V DC
- Standby: 24V DC
- Max Loop Current: 500mA
- Number of Supported Zones: 32
- LCD Display: LCD Graphical Display
- Device Labels: 31 Characters
- Event Log: 1000 Events
- Repeater Panels: 8 Max
- Aux Power Output: 30V DC 450mA
- Inputs and Outputs: Inputs: 2 x Monitored Inputs (3k3 EOL, 680R Firing Resistor)
- Outputs: 3 x Volt Free Relay (30V DC @ 1A Max)
- Monitored Outputs 2 x (24V DC @ 500mA Max, 10k EOL)
Declaration of Performance
- FIKE-CIE-A-200 DoP 520-0001
- Sita ASD NS DoP 205-0003
- Sita ASD WS DoP 205-0001
- Sita ASD WSS DoP 205-0012
- Sita MCP DoP 403-0006
- Sita MCP WP DoP 403-0007
- Sita Sounder DoP 326-0001
- Sita Sounder DoP 326-0003
- Sita Sounder Strobe DoP 326-0021-R
- Sita Sounder Strobe DoP 326-0023-R
- Sita Soundpoint DoP 313-000X
- Sita Hipoint DoP 323-0001
- Sita IO DoP 803-0006
- Sita CZM DoP 803-0010
Manuais
- CIE-A-200 Eng&ComManual
- CIE-A-200 Panel UserGuide
- Sita MP ASD Installation Instructions
- Sita MP IO Boxed Module Installation Instructions
- Sita MCP Installation Instructions
- Sita MCPWP Installation Instructions
- Sita Sounder Deep Base Installation Instructions
- Sita Sounder Low Profile Installation Instructions
- Sita Sounder Strobe Deep Base Installation Instructions
- Sita Sounder Strobe Low Profile Installation Instructions
- Sita Strobe WP Installation Instructions
- Sita SoundPoint Installation Instructions
- Sita HiPoint Installation Instructions
- Sita Loop IO Installation Instructions
- Sita Conventional Zone Module Installation Instructions