Fire Protection Systems
When protecting buildings and mission-critical assets, every second counts. Fike’s comprehensive fire protection systems can detect a fire in its earliest stages and suppress it without causing any collateral damage, all occurring within just seconds of combustion.
Fire Panels
Include addressable and conventional configurations, suppression system activation, voice evacuation, emergency power shutdown, and more.
Fike FCP | Fike Cheetah® Xi | Fike SHP PRO® | |
---|---|---|---|
Function |
Addressable control panel with comprehensive functionality |
Addressable, modular fire alarm and suppression system |
Conventional fire alarm and suppression panel |
Benefit |
Supports up to 159 sensors and modules per loop; ECS models include voice evacuation functions. |
Integrates with clean agent water mist systems; Xi 50 supports up to 50 devices, and Xi 1016 up to 1016 devices. |
Designed to serve the needs for smaller applications; supports 25 convention devices per circuit. |
Approvals |
UL | FM |
UL | FM |
UL | FM |
Air Sampling
Continuously measures a room's air quality for early signs of combustion, even before smoke is visible.
VESDA-E-VEP | VESDA-E VES | VESDA-E VEU | VESDA-E VLI | VESDA-E VEA | |
---|---|---|---|---|---|
Function |
Mainstream aspirating smoke detector |
Sector addressable aspirating smoke detector |
Highest sensitivity aspirating smoke detector |
Industrial aspirating smoke detector |
Centralized aspirating smoke detector |
Benefit |
Combines advanced air sampling detection technology with flexibility for use in a wide range of applications. |
Monitors smoke density by individual pipe, allowing a single zone to be divided into four sectors where pinpoint location is essential. |
Offers an ultra-wide sensitivity range, long linear piperuns and more sampling holes, ideal for high airflow or high-ceiling environments. |
Designed to protect industrial applications and harsh environments with a fail-safe intelligent filter and advanced clean-air barrier. |
Includes the performance of smoke detectors with centralized testing and maintenance; ideal for hospitals, hotels and other highly populated buildings. |
Approvals |
UL | ULC | FM | VdS | CE | CSFM | NF-SSI | VNIPO | ActivFire | CCC | EN |
UL | ULC | VdS | CE | CSFM | ActivFire | EN 54-20 | ISO 7240-20 |
UL | ULC | FM | VdS | CE | CSFM | NF-SSI VNIPO | ActivFire | CCC | EN 54-20 | ISO 240-20 |
UL | ULC | FM | CE | ActivFire,UKCA | LPCB | NF | SIL 2 | EN54-20 |
UL | ULC | FM | VdS | CE | CSFM | EN 54-20 | ISO 7240-20 | ActivFire |
Flame Detectors
Quickly identifies hydrocarbon fuel and gas fires. Operates in all weather and light conditions; triple spectrum technology provides immunity to false alarms.
FIK-IR3 | FIK-IR3-H2 | FIK-UV-IR | FIK-HD | Fike Fire Watch | |
---|---|---|---|---|---|
Function |
Hydrocarbon flame detector |
Hydrogen flame detector |
Hydrocarbon and hydrogen flame detector |
Optional HD camera |
Deployable fire watch unit |
Benefit |
Detection within 40 milliseconds of fireballs or explosions; detects standard fires 50 ft away within 1.3 seconds, and fires 230 ft away within 3.7 seconds. |
Detection within 40 milliseconds of fireballs or explosions; detects hydrogen fires 0-66 ft away within 1.2 seconds, and fires 67-100 ft away within 4 seconds. |
Ultra fast detection within 5 milliseconds of fireballs or explosions; detects fires up to 100 ft away for a 1ft n-heptane fire. |
Provides live video feed and recording one minute pre-event and three minutes post-event. Fike Video Analytics may also be integrated for oil mist and smoke detection. |
Equipped with one or two Fike flame detectors, satisfies temporary or long-term fire watch needs after hot work or if a fire protection system is disabled. |
Approvals |
ATEX | IECEx | FM | FMC | CSFM | INMETRO |
ATEX | IECEx | FM | FMC | CSFM | INMETRO |
ATEX | IECEx | FM | FMC | CSFM | INMETRO |
ATEX | IECEx | FM | FMC | CSFM |
FM-review |
Linear Heat Detection
A continuous run of heat detectors within a versatile cable; designed for use in a variety of indoor and outdoor applications and harsh environments.
Digital Temperature Sensing (DTS) | Protectowire | |
---|---|---|
Function |
Fiber optic distributed temperature sensing cable |
General purpose linear heat cable |
Benefit |
Provides continuous temperature profile along the entire length of the sensor cable to identify the location of overheated areas before they become hazardous. |
Activates alarm once fixed temperature is reached anywhere along the cable; suited for areas where access is difficult or hazardous. |
Approvals |
UL | FM | ULC | CE | VDS |
UL | FM | CSFM |
Video Detection
Uses live video technology to monitor hazards such as oil mist or overheated surfaces which are difficult to identify with other detection methods.
Fike Video Analytics | Thermal Imaging Cameras | |
---|---|---|
Function |
Flame, smoke and oil mist detection system |
Temperature monitoring technology |
Benefit |
May be integrated on existing or new camera networks to provide advanced notification of an impending hazard prior to activating fire alarm, suppression and evacuation systems. |
Visualizes obscured fires and monitors temperature of potential overheated malfunctioning equipment; generates report to log temperature data to identify where maintenance is required. |
Approvals |
UL | FM | CE |
|
Gas Detection
Provides early warning of the presence of gases for occupant protection and system monitoring.
Sensepoint XCD | Sensepoint XCL Large Bore | Sensepoint XCL Micro Bore | Li-ion Tamer Gas Detection | |
---|---|---|---|---|
Industrial gas detector |
Aspirating gas detector |
Aspirating gas detector |
Energy storage system gas detector |
|
Monitors flammable and toxic gas hazards in industrial and commercial environments; comes pre-configured and offers simple installation on surfaces and horizontal or vertical pipes. |
Used in tandem with an Xtralis aspirating smoke detection pipe network to identify early warning signs of both harmful or explosive gasses and fire hazards. |
Used in tandem with an VESDA-E VEA aspirating smoke detection pipe network to identify early warning signs of both harmful or explosive gasses and fire hazards. |
Monitors battery energy storage systems for off-gas of a malfunctioning lithium ion battery; connects with BMS or fire panel to shut down power. |
|
EN/UL/IEC 61010-1 | CE | UL2075 |
CE | ETL | EN/UL/IEC 61010-1 | CE | UL2075 |
CE | EN | UL | EN/UL/IEC 61010-1 | CE | UL2075 |
CE | ETL | ETL listed to UL 61010 | EN 61326 | RoHs 3 EU 2015/863 |
|
Bi-Directional Amplifiers (BDAs)
Also known as Emergency Responder Communication Enhancement Systems (ERCES), BDAs are required by both international building and fire codes, as they upgrade the in-building radio signal to provide reliable, two-way communications for safety personnel.
Chemical Agent Fire Suppression
Waterless, electrically non-conductive suppressing agents which remove heat and dissolve fires at the molecular level.
3M™ Novec™ 1230 | FK-5-1-12 | FM-200™ | ECARO-25® | Small Space | |
---|---|---|---|---|---|
Function |
Fluoroketone agent |
Fluoroketone agent |
Hydrofluorocarbon agent |
Hydrofluorocarbon agent |
Heat-reactive tubing |
Benefit |
Has a global warming potential of less than one, 99.9 percent less than hydrofluorocarbons. |
Viable alternative to 3M Novec 1230; may have quicker lead times. |
Most used and globally recognized chemical agent. |
Cost-effective chemical agent; requires 20 percent less agent per cubic/meter than FM-200. |
Flexible tubing routed through electrical cabinets or CNC machines to provide agent immediately within these confined spaces. |
Approvals |
CE | EN | UL | ULC | FM |
FM | UL | ULC |
FM | UL | ULC | CE |
FM | UL | ULC |
UL |
Water-Based Suppression
Ideal for many applications where traditional sprinkler systems would result in destroyed electronics, collateral damage and excessive cleanup, and uses up to 90 percent less water than conventional fire sprinkler systems.
DuraQuench® | Micromist® | Fire Water Monitors | |
---|---|---|---|
Function |
Engineered skid-mounted pump system |
Pre-engineered, self-contained water mist system |
Flame, smoke and oil mist detection system |
Benefit |
Connects directly to a building’s water supply, tank or reservoir to provide an unlimited discharge of water mist; may protect volumes with 75 percent less water than a conventional sprinkler system. |
Pre-assembled with all necessary components to offer a simple-to-install water mist solution; particularly suited for applications where a water source is unavailable. |
Discharges up to 1,320 gallons per minute up to 87 yards away in a total nozzle spray pattern; frequently combined with Fike flame detectors to create the ultimate early warning water- or foam-based fire suppression solution. |
Approvals |
FM | NFPA 750 |
FM | NFPA 750 (intermediate pressure system) |
|
Inert Gas Suppression
Inert gas is used to reduce oxygen levels to a concentration unsustainable for fires but safe for people and the environment. Its superior design qualities allow for long pipe runs and small-diameter piping with low pressure ratings and couplings from the inert gas containers all the way to the nozzles.
Carbon Dioxide (CO2) Suppression
Reduces oxygen to a point where combustion cannot occur or be sustained. Extremely effective and versatile for Class A, B or C hazards, and is often used to protect localized applications.